Product Features
Powerful Features. High Efficiency.
The C2000 Series AC motor drive provides the most efficient solution for all types of drive applications. It features precise speed, torque and position control functions that are suitable for both sensor and sensorless types of synchronous and asynchronous motors. The C2000 Series is also equipped with built-in PLC functions and supports the CANopen Master/Slave extension for the ultimate in system flexibility and fast data exchange.
Control Characteristics | Control Method | Pulse Width Modulated (PWM) |
Control Mode | 230 V / 460 V model: 575 V / 690 V model: | |
Starting Torque | Reach up to 150% or above at 0.5 Hz. Under FOC+PG mode, starting torque can reach 150% at 0 Hz | |
V / F Curve | 4-point adjustable V / F curve and square curve | |
Speed Response Ability | 5 Hz (vector control can reach up to 40 Hz) | |
Torque Limit | 230 V / 460 V model: Normal duty 160%, heavy duty 180% of torque current; 575 V / 690 V model: Maximum 200% of torque current | |
Torque Accuracy at TQC Mode | TQC + PG:±5% TQC Sensorless:±15% | |
Max. Output Frequency (Hz) | Light Duty / Normal duty: 0.01 ~ 599.00 Hz; Heavy duty: 0.00 ~ 300.00 Hz | |
Frequency Output Accuracy | Digital command: ±0.01%, -10 ° C ~ +40 ° C, Analog command: ±0.1%, 25 ±10 ° C | |
Output Frequency Resolution | Digital command: 0.01 Hz, Analog command: 0.03 * max. output frequency / 60 Hz (±11 bit) | |
Frequency Setting Signal | +10 V ~ -10V, 0 ~ +10 V, 4 ~ 20 mA, 0 ~ 20 mA, pulse input | |
Accel. / decel. Time | 0.00 ~ 600.00 / 0.0 ~ 6000.0 Seconds | |
Main Control Function | Torque control, Speed / torque control switching, Feed forward control, Zero-servo control,Momentary power loss ride thru, Speed search, Over-torque detection, Torque Limit, 16-step speed (Max.),Accel / decel time switch, S-curve accel / decel, 3-wire sequence, Auto-Tuning (rotational, stationary), Dwell,Slip compensation, Torque compensation, JOG frequency, Fault restart,Frequency upper / lower limit settings, DC injection braking at start / stop, High slip braking, Parameter copy PID control (with sleep function), Energy saving control, MODOBUS communication (RS-485 RJ45, Max.115.2 kbps) | |
Fan Control | 230 V model: VFD150C23A (include) and series above: PMW control; VFD110C23A and below: on / off switch control 460 V model: VFD185C43A (include) and series above: PMW control; VFD150C43A and below: on / off switch control 575 V / 690 V model: PWM control | |
Protection Characteristics | Motor Protection | Electronic thermal relay protection |
Over-Temperature Protection | Built-in temperature sensor | |
Stall Prevention | Stall prevention during acceleration, deceleration and running independently | |
Restart after Instantaneous Power Failure | Parameter setting up to 20 seconds | |
Grounding Leakage CurrentProtection | Leakage current is higher than 50% of rated current of the AC motor drive | |
International Certifications | CE UL EAC |